Fitting The Trim Or Fascia; Fitting The Fender; Checking For Clearance Of Combustion Products - Flavel Linear Installation, Maintenance & User Instructions

Decorative fuel-effect gas fires
Table of Contents

Advertisement

3.7
FITTING THE TRIM (KENILWORTH MODELS ONLY) OR LINEAR
FASCIA
3.7.1
The trim or Linear fascia is held in position on the fixing flange by
magnets.
3.8
FITTING THE FENDER (KENILWORTH MODELS ONLY)
3.8.1
The fender is placed up to the front of the ceramic front rail on
all models. Position the ashpan under the fender and centralise.
3.9

CHECKING FOR CLEARANCE OF COMBUSTION PRODUCTS

3.9.1
Close all doors and windows in the room.
3.9.2
Light the fire and allow to run for approximately 5 minutes on high
position.
3.9.3
After approximately 5 minutes hold a smoke match just inside and
below the centre of the lower front edge of the top of the fire. (It is
recommended that a suitable smoke match holder is used when check
ing for clearance of combustion products). All smoke generated should
be drawn back into the flue. If slight spillage occurs or if in doubt,
repeat the test after a further 5-10 minutes. If the test indicates that
spillage is occurring and the flue restrictor baffle has been fitted, it
should be removed and the test repeated after the fire has cooled.
3.9.4
If spillage persists with the restrictor baffle removed, the flue is not
functioning correctly and a fault exists. If, after investigation the fault
cannot be traced and rectified, the fire must be disconnected from the
gas supply and expert advice obtained.
3.9.5
If there is an extractor fan fitted any where in the vicinity of the
appliance, the spillage test should be repeated with the fan running on
maximum and all interconnecting doors open.
After ensuring that the fire is safe to use it should be left on high
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
At this stage any minor adjustments to the coals / pebbles should be
made using suitable long handled tongs and taking care not to damage
the coals or pebbles.
Finally, hand the Installation and Maintenance Instructions and the
Users Instructions over to the customer and explain the operation of the
fire.