Information And Requirements; Appliance Information - Flavel FBFC**MN2 Installation, Maintenance & User Instructions

Calibre
Table of Contents

Advertisement

1.0

APPLIANCE INFORMATION

Main injector : (1 off)
Pilot Type - S.I.T.140 Series
Max. Gross Heat Input :
Min. Gross Heat Input :
Gas Rate :
Cold Pressure :
Ignition :
Ignition :
Electrode Spark Gap :
Weight (without fender) :
Fig 1
580mm
550mm

INFORMATION AND REQUIREMENTS

185mm
285mm Min, 625mm Max with standard flue
duct on MC / RC models. 248mm Min,
588mm Max with standard flue duct on EFC
models. A cost option extended flue duct (part
no. CV-MARLT) can be purchased to increase
this dimension on NG MC / RC models to
1010mm or 973mm on NG EFC models)
SECTION 1
Natural Gas
1.65mm
Size 27
4.6kW
3.2kW
0.427 m 3 /hr
20.0+/-1.0 mbar
Push-button Piezo (MC models only)
Electronic (RC & EFC models only)
4.0mm
25.0 kg inclusive of flue pipe and terminal
3
LPG
1.20mm
Size 19
4.8kW
3.4kW
0.180 m 3 /hr
37.0+/-1.0 mbar
150mm
120mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fbfc**rn2Fbfc**en2Fbfc**mp2

Table of Contents