7.2 Changing oil
Drain the oil while the engine is still warm to assure rapid and complete draining.
Oil drain bolt
Oil dispstick
Fig.13
1. Open the left side maintenance cover.
2. Take out the oil outlet plug.
3. Remove the drain bolt, and drain the oil. Retighten the bolt securely.
4. Refill with the recommended oil and check the level.
5. Close the left side maintenance cover.
Engine oil capacity: 0.6L
NOTE
Please dispose of used motor oil in a manner that is compatible with the
environment. We suggest you take it in a sealed container to your local
serv-ice station for reclamation. Do not throw it in the trash or pour it
on the ground.
7.3 Air cleaner service
A dirty air cleaner will restrict air flow to the carburetor to prevent carburetor
malfunction, service the air cleaner regularly. Service more frequently when oper-
ating the generator in extremely dusty areas.
WARNING
Do not use gasoline or low flash point solvents for cleaning. They are
flammable and explosive under certain conditions.
CAUTION
Never run the generator without the air cleaner. Rapid engine wear may result.
Upper limit
Lower limit
-16-
5.3 DC application
The DC receptacle may be used for charging 12 volt automotive-type batteries only.
Output voltage is 15-30V when current receptacle on no load. DC output will vary
according to the position of the Smart throttle switch.
DC current:
SMART throttle switch
Model
IG3000
1.Connect the charging cable to the DC receptacle of the generator and then to the
battery terminals.
WARNING
To prevent the possibility of creating spark near the battery, connect charg-
ing cable first to the generator, then to the battery. Disconnect cable first at
the battery.
Before connecti g charging cable to a battery that is installed in a vehicle,
n
disconnect the vehicles grounded battery cable. Reconnect the vehicle's
grounded
battery cable after the charging cables are removed. This
proceddure will prevent the possibility of a short circuit and sparks if you
make accidental contact between a battery terminal and the vehicle's frame
or body.
CAUTION
Do not attempt to start an automobile engine with the generator still conn-
ected to batter. The generator may be damaged. Connect the positive
battery terminal to the positive charging cord. Do not reverse the charging
cables, or serious damage to the generator and/or battery may occur.
WARNING
The battery gives off explosive gases; keep sparks, flames and cigarettes
away. Provide adequate ventilation when charging.
The battery contains sulfuric acid (electrolyte). Contact with skin or eyes
may cause severe burns. Wear protective clothing and a face shield.
A. If electrolyte gets on your skin, flush with water.
B.If electrolyte gets in your eyes, flush with water for at least 15 minutes
and call a physician.
Electrolyte is poisonous.
If swallowed, drink large quantities of water or milk and follow with milk of
magnecia or vegetable oil and call a physician.
ON
OFF
(do not use the AC output)
approximately 2.8A
5.0A
-13-