Download Print this page

Kipor Sinemaster IG3000 Operation Manual page 16

Hide thumbs Also See for Sinemaster IG3000:

Advertisement

5.1 AC applications
1. Start the engine and make sure the green output indicator light comes on.
2. Confirm that the appliance to be used is switched off and plug in the appliance.
Fig. 12
CAUTION
Be sure that all appliances are in good working order before connecting
them to the generator. If an appliance begins to operate abnormally, becomes
sluggish, or stops suddenly, turn off the generator engine switch immediately.
Disconnect the appliance and examine it for signs of malfunction.
5.2 Output and Overload Indicators
The green output indicator light will remain ON during normal operating conditions. If
the generator is overloaded or if there is a short in the connected appliance the
output indicator will go OFF and the overload indicator will go ON and current to the
connected appliance will be shut off.
Stop the engine if the overload indicator light comes ON and investigate the
overload source. The engine will continue to run even though it is not producing any
AC power. The engine must be stopped and then the generator restarted to resume
normal operation.
Check the engine oil level if the red oil alarming indicator comes ON.
Before connecting an appliance to the generator, check that it is in good
order, and that its electrical rating does not exceed that of the generator.
Then connect the power cord of the appliance, and start the engine.
When an electric motor is started, both the overload indicator light and the
output indicator light may go on simultaneously. This is normal if the overload
indicator light goes off after about four seconds. If the overload indicator light
stays on, consult your dealer.
NOTE
NOTE
-12-
1.Open the left side maintenance cover.
2.Unsnap the clips, remove the air cleaner cover.
3.Take out the element, blow the inner side of the element with compressed air to
remove the dust. If the element is very dirt, please replace it.
4.Reinstall the air cleaner cover, close the left side maintenance cover.
Air cleaner base
Air cleaner element
Air cleaner cover
Fig 14
7.4 Spark plug service
Recommended spark plug:
WR7DC
To ensure proper engine operation, the spark plug must be properly gapped and
free of deposits.
1. Open the left side maintenance cover.
2. Remove the spark plug cap.
3.
Use the wrench to remove the spark plug.
4.
Clean any dirt from around the spark plug base.
Spark plug wrench
Fig.15
Blow the inner side of the
element with compressed air
Air cleaner element
Spark plug lover
-17-

Hide quick links:

Advertisement

loading