2. INSTALLATION

2.1 INSTALLATION REQUIREMENTS

2.1.1 ENVIRONMENT

1.
Temperature Range: 10°C to 32°C (50°F to 89.6°F)
2.
Humidity Range: 15% to 80% RH
3.
Ambient Illumination: Less than 1500 lux (do not expose to direct sunlight)
4.
Ventilation: 3 times/hr/person or more
5.
Do not let the machine get exposed to the following:
1) Cool air from an air conditioner
2) Heat from a heater
6.
Do not install the machine in areas that are exposed to corrosive gas.
7.
Install the machine at locations lower than 2,000 m (6,500 ft.) above sea level.
8.
Install the machine on a strong, level base. (Inclination on any side must be no more than 5
mm.)
9.
Do not install the machine in areas that get strong vibrations.

2.1.2 MACHINE LEVEL

Front to back: Within 5 mm (0.2")
Right to left: Within 5 mm (0.2")