Image Adjustment

Scanner leading edge and side-to-side registration

A: Leading Edge Registration
1.
Put the test chart on the exposure glass. Then make a copy from one of the feed stations.
2.
Check the leading edge and side-to-side registration. Adjust the following SP modes if
necessary.
Standard: 0 ± 2mm for the leading edge registration, 0 ± 2.5mm for the side-to-side
registration.
Leading Edge Registration
Side-to-Side Registration
D117/D118
SP mode
SP4-010-001
SP4-011-001
4-4