Fujitsu Eternus DX60 S2 User Manual page 32

Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Chapter 2 Standard Operations
2.1 Powering On and Off
IMPORTANT
Procedure
1
2
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
After turning the power on, it takes about three minutes for the
ETERNUS DX Disk storage system to become READY (i.e. the READY
LED turns on). If an error is detected during the initial power-on
diagnostic phase, a longer time (up to ten minutes) may be required
before the READY LED turns on.
Before turning the server on, check that the ETERNUS DX Disk storage
system and the network devices that connect the ETERNUS DX Disk
storage system and the server are all in READY status. If the server is
turned on while any of these devices are not in READY status, the
server may not be able to recognize the ETERNUS DX Disk storage
system.
When the AUTO POWER switch of the controller enclosure is turned to
"ON", supplying power to the ETERNUS DX Disk storage system will
cause the ETERNUS DX Disk storage system to turn on automatically in
cases such as when the power cord is connected or the power is
recovered after power failure.
Press the power switch ( ) of the controller enclosure.
Controller enclosure POWER LED turns on.
When drive enclosures are installed, the power turns on
automatically.
Power switch
After three minutes, check that the READY LED on the controller enclosure are
lit up.
Copyright 2011 FUJITSU LIMITED
Drive Enclosure
Controller Enclosure
32
P3AM-5512-02ENZ0