Fujitsu Eternus DX60 S2 User Manual page 100

Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
and event
M E207000B
M E207000C
M E207000D
M E207000E
M E207000F
M E2070010
M E2070011
M E2070015
M E2070016
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
Maintenance
code
No.
Info
7
E207000B
NOT READY(11:Power Off/Fail Incomplete)
The device is in Not Ready status.
Failed to power off. Or the device power turns off
immediately after the device powers on.
7
E207000C
NOT READY(12:Backup Fail)
The device is in Not Ready status.
Backup failed.
7
E207000D
NOT READY(13:Multi CM Down)
The device is in Not Ready status.
Adjoining CMs with LUs are degraded.
7
E207000E
NOT READY(14:Machine Down Recovery End)
The device is in Not Ready status.
Machine down recovery is performed.
7
E207000F
NOT READY(15:Machine Down Recovery Failed)
The device is in Not Ready status.
Failed to perform machine down recovery.
7
E2070010
NOT READY(16:DE Build Error)
The device is in Not Ready status.
Failed to configure DE because of miniSAS cable errors
or FC cable errors.
7
E2070011
NOT READY(17:CM Memory Shortage)
The device is in Not Ready status.
Memory capacities are smaller than the minimum value in
multiple CMs.
7
E2070015
NOT READY(21:Configuration Data restored from
System Disk)
Maintenance is performed for the CM in cold mode.
The ETERNUS DX Disk storage system normally powers
off and then on, and the status becomes Ready.
7
E2070016
NOT READY(22:No Version)
The device is in Not Ready status.
The version table is invalid.
Copyright 2011 FUJITSU LIMITED
Upper: Message
Lower: Description
100
Remarks
These messages
are notified when
the relevant event
occurs.
P3AM-5512-02ENZ0

Advertisement

Table of Contents
loading

Table of Contents