Figure 1.15 Power Supply Unit - Fujitsu Eternus DX60 S2 User Manual

Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Chapter 1 Components
1.1 Controller Enclosure
SAS (HOST)
LINKUP/FAULT
UNIT READY/
FAULT
MASTER
ACT
LINK
System Capacitor Unit (SCU)
A SCU is installed in a controller as a backup power source in case of power outage.
The SCU is charged from an external power source while the ETERNUS DX Disk storage
system is running normally. If a power outage is detected, data in the cache memory is saved to
a non-volatile memory in the controller using the SCU. The saved data is retained in the non-
volatile memory indefinitely.
1.1.4.2
Power Supply Units
The power supply unit transforms input AC power from a power socket to DC power and supplies
power to each component.
Each power supply unit contains fans.

Figure 1.15 Power supply unit

Part explanation
Inlet
This inlet is used to connect a power cord.
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
LED name
LED status
(green)
(orange)
(green)
(orange)
(green)
(green)
(green)
STATUS LED
Copyright 2011 FUJITSU LIMITED
The link between the SAS port (host interface port) and
the destination has been established.
The SAS port (host interface port) is in error status.
The controller is in normal status.
The controller is performing the initial setup after the
power is turned on.
The controller is in error status.
The controller is set as a Master CM.
The controller is sending or receiving data via the LAN
port (for operation management).
The link between the LAN port (for operation
management) and the destination has been
established.
Inlet
21
Controller status
P3AM-5512-02ENZ0

Advertisement

Table of Contents
loading