Complete The Installation; Seasonal Heat Dump Operation - kozy heat 944 Installation And Operation Manual

Direct vent see-thru / pier gas fireplace
Table of Contents

Advertisement

COMPLETE THE INSTALLATION

1.
COMPLETE THE FIREPLACE WALLS AND THE UNIT FACING.
SECURE THE FIREPLACE:
Note: Nailing flanges are attached to the fireplace vented end and nailing tabs are at the top of the non-vented end.
Vented end:
1. Loosen but do not remove the screws securing the nailing flanges on the vented end of the fireplace and remove the flanges.
2. Place the keyhole slots on the nailing flanges over the screws and slide forward to the desired position then tighten the screws.
3. Vent the flanges so they are parallel with the fireplace.
4. Fasten the nailing flanges to the framing through the holes in the nailing flange.
Nailing Flanges
Vented End
Top: Bend the nailing tabs on at the top of the non-vented end „up‟ and secure to the framing with screws.
WARNING:
DO NOT ENCLOSE THE AIR SPACE AT THE BOTTOM OF THE FIREPLACE. THIS COULD CAUSE THE AREA TO OVERHEAT.
MASONRY CONSTRUCTION: If using a lintel iron, follow instructions included with the lintel iron for proper placement.
CAUTION:
The surrounding wood chase of the outside wall MUST be insulated to prevent cold air from
entering the room.
SEASONAL HEAT DUMP POSITION:
This fireplace has been designed with an adjustable heat dump outlet located in the baffle inside the fireplace (at the top). This will allow infinite control
over the amount of heat emitted into the living area without affecting the flame height.
INSTALLER: PLEASE INSTALL THIS FIREPLACE WITH THE ADJUSTABLE HEAT OUTLET DUMP IN ITS CLOSED POSITION.
HOMEOWNER: The fireplace has been installed with the heat dump in the closed position and will operate at its peak efficiency. The heat dump may be
opened as much as necessary to maintain heat level.
TO ADJUST:
CAUTION: DO NOT ATTEMPT TO ADJUST THE HEAT DUMP OPENING IF THE FIREPLACE HAS BEEN IN OPERATION. ALLOW
AMPLE TIME TO COOL OR USE THE APPROPRIATE PROTECTION TO AVOID SERIOUS BURNS AND / OR PROPERTY DAMAGE.
1.
Remove the „front‟ glass assembly and set aside where it will not be broken.
Refer to page #7.
2.
Locate the heat dump damper handle in the baffle and adjust opening to amount
desired.
3. Replace the front glass assembly.
NOTE: The more open the heat dump, the less heat that will be emitted into the living
area. This enables you to operate the fireplace for a longer period of time
without overheating the room.
Figure 16
HEAT OUTLET SHOWN IN PARTIAL OPEN POSITION
PAGE 23
Top Nailing Tabs
Non-Vented End