Dsp Module - Aastra 415 System Manual

Hide thumbs Also See for 415:
Table of Contents

Advertisement

Please note:
• The arrows on the wiring adapters specify the plug-in orientation of the required
port assignment.
• On the ESST terminal card the jumper must always be fitted in position T (see fig-
ure below). The port assignment is specified by the wiring adapter alone.
Jumper in
position T:
Fig. 24
Jumper position on ESST card
Note
Any incorrectly fitted or missing wiring adapters are signalled by a red
flashing LED on the display after start-up (see
tion Mode", page
4. 5. 3

DSP module

DSP modules belong to the category of system modules and are fitted to the SM1
slot (see
Fig.
7). Three DSP modules are stackable.
Warning
Be sure to observe the
1. Shut down the communication server (see
disconnect it from the power supply.
2. Remove the housing cover.
3. Remove the fastening screw from module slot SM1.
4. Instead of the fastening screw, screw in the spacer sleeve enclosed with the
module.
5. Place the module on slot SM1 of the communication server (or onto a module al-
ready fitted in that slot) and press down evenly on both connectors as far as the
stop.
6. Secure the module with the fastening screw.
7. Fit the housing cover.
8. Reconnect the communication server to the power supply.
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Card ESST-2
T
S
NC
NC
S/T
RIGHT
209).
"Safety regulations", page
Card ESST-2
Jumper in
NC
NC
position S:
S/T
WRONG
"Wiring Adapter Malfunc-
82.
"Shutdown Mode", page
Installation
T
S
S
211) and
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

430

Table of Contents