Models With Heating; Stop Buffer At Clutch Side - Stihl MS 261 User Manual

Hide thumbs Also See for MS 261:
Table of Contents

Advertisement

9.4.1

Models with Heating

4
– Push the air guide shroud (1) in
direction of rear handle.
: Take out the screws (2) and (3).
: Remove the complete AV
spring (4).
1
2
: Unscrew the bearing plug (1) and
disconnect the retainer (arrow).
: Unscrew the spring (2) and pull
out the retainer (arrow).
MS 261, MS 261 C
Installing
1
3
2
2
: Fit the retainer (1) in the
bracket (2) and engage the
nipple.
1
: Screw the spring (2) onto the
peg.
: Attach the retainer (arrow) to the
bearing plug (1).
: Screw the bearing plug (1) into
the spring (2) as far as stop.
4
: Position the AV spring (4) on the
handlebar and cylinder.
: Insert and tighten down the
screw (2) firmly.
: Push the air guide shroud (1) in
direction of rear handle.
: Coat the screw (3) with Loctite, fit
it and tighten it down firmly, b
1
– Reassemble all other parts in the
reverse sequence.
9.5
The stop buffers are located
between the tank housing and
crankcase. They are fitted at the
ignition and clutch sides.

Stop buffer at clutch side

1
2
: Pry out the stop buffer (1) at the
recess (arrow).
– Check the stop buffer and
replace if necessary.
1
3
2
b 15
Stop Buffer at Clutch
Side
79