Aeration Setting Check; Ceramic Fuel Bed Installation; Ceramic Walls Installation - Valor 530SAN Installation And Owner's Manual

Direct vent gas fireplace heater with logs or coals
Table of Contents

Advertisement

The burner is equipped with an adjustable shutter to control primary
aeration. See figure 60. The shutter is factory set at an aeration gap which
will give optimum performance for the vast majority of installations. In a
few unusual installations performance may be improved by adjusting the
aeration. The need for adjustment should be determined by operating the
appliance with the ceramic fuel effects and window installed. See the
"Final checks" section in this manual for adjustment details.
The shutter setting is very critical. A change of
substantial difference to the performance.

14. CERAMIC FUEL BED INSTALLATION

14.1. Ceramic Walls Installation

1.
Locate the ceramic rear wall in the channel at back of the firebox and flat against the back of the firebox. See figure 61.
2.
Locate the side walls in the channels at the sides of the firebox. See figure 62.
3.
Remove two screws from under the top front of the firebox. Using these screws, fit the port cover. See figure 63.
Figure 61

13. AERATION SETTING CHECK

1
/
" can make a
64
Figure 62
35
Figure 60
Figure 63