Troubleshoot An Under-Voltage Condition; Buffer Tuning - Dell S6000–ON Configuration Manual

Hide thumbs Also See for S6000–ON:
Table of Contents

Advertisement

Troubleshoot an Under-Voltage Condition

To troubleshoot an under-voltage condition, check that the correct number of power supplies are
installed and their Status light emitting diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs on the environmental monitoring hardware
and hardware components.
Table 105. SNMP Traps and OIDs
OID String
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7
Hardware MIB Buffer Statistics
.1.3.6.1.4.1.6027.3.16.1.1.4
.1.3.6.1.4.1.6027.3.16.1.1.5
.1.3.6.1.4.1.6027.3.16.1.1.6

Buffer Tuning

Buffer tuning allows you to modify the way your switch allocates buffers from its available memory and
helps prevent packet drops during a temporary burst of traffic.
The application-specific integrated circuit (ASICs) implement the key functions of queuing, feature
lookups, and forwarding lookups in hardware.
Debugging and Diagnostics
OID Name
chSysPortXfpRecvPower
chSysPortXfpTxPower
chSysPortXfpRecvTemp
fpPacketBufferTable
fpStatsPerPortTable
fpStatsPerCOSTable
Description
OID displays the receiving power
of the connected optics.
OID displays the transmitting
power of the connected optics.
OID displays the temperature of
the connected optics.
NOTE: These OIDs only
generate if you enable the
enable optic-info-
update-interval is
enabled command.
View the modular packet buffers
details per stack unit and the
mode of allocation.
View the forwarding plane
statistics containing the packet
buffer usage per port per stack
unit.
View the forwarding plane
statistics containing the packet
buffer statistics per COS per port.
1043