Table of Contents
5
1 Introduction to the Variable Wavelength Detector
9
Introduction to the Detector
10
Optical System Overview
11
System Overview
16
2 Site Requirements and Specifications
19
Site Requirements
20
Physical Specifications
24
Performance Specifications
25
3 Installing the Detector
31
Unpacking the Detector
32
Delivery Checklist
33
Detector Accessory Kit Contents
33
Optimizing the Stack Configuration
34
One Stack Configuration
34
Two Stack Configuration
37
Installation Information on Leak and Waste Handling
39
Installing the Detector
43
Flow Connections to the Detector
46
4 Using the Detector
49
Leak and Waste Handling
50
Setting up an Analysis
51
Before Using the System
51
Requirements and Conditions
53
Optimization of the System
55
Preparing the HPLC System
56
Running the Sample and Verifying the Results
65
Special Settings of the Detector
66
Control Settings
66
Online Spectra
67
Scanning with the VWD
68
Analog Output Settings
69
Special Setpoints
70
5 How to Optimize the Detector
73
Optimizing the Detector Performance
74
Match the Flow Cell to the Column
75
Set the Detector Parameters
78
6 Troubleshooting and Diagnostics
79
Overview of the Detector's Indicators and Test Functions
80
Status Indicators
81
Power Supply Indicator
81
Module Status Indicator
82
Available Tests Versus Interfaces
83
Agilent Lab Advisor Software
84
7 Error Information
85
What Are Error Messages
86
General Error Messages
87
Timeout
87
Shutdown
88
Remote Timeout
88
Lost CAN Partner
89
Leak
90
Leak Sensor Open
90
Leak Sensor Short
91
Compensation Sensor Open
91
Compensation Sensor Short
92
Fan Failed
92
Open Cover
93
Detector Error Messages
94
UV Lamp: no Current
94
UV Lamp: no Voltage
94
Ignition Failed
95
No Heater Current
96
Wavelength Calibration Setting Failed
97
Wavelength Holmium Check Failed
98
Grating or Filter Motor Errors
98
Wavelength Test Failed
99
Cutoff Filter Doesn't Decrease the Light Intensity at 250 Nm
100
ADC Hardware Error
100
Cover Violation
101
8 Test Functions
103
Intensity Test
104
Intensity Test Failed
105
Cell Test
106
Wavelength Verification-Calibration
108
ASTM Drift and Noise Test
110
Quick Noise Test
111
Dark Current Test
112
Dark Current Test Failed
113
Holmium Oxide Test
114
Holmium Oxide Test Failed
116
9 Maintenance
117
Introduction to Maintenance
118
Warnings and Cautions
119
Overview of Maintenance
121
Cleaning the Module
122
Exchanging a Lamp
123
Exchanging a Flow Cell
126
Repairing the Flow Cells
128
Using the Cuvette Holder
130
Correcting Leaks
132
Replacing Leak Handling System Parts
133
Replacing the Interface Board
134
Replacing the Module's Firmware
135
10 Parts and Materials for Maintenance
137
Overview of Maintenance Parts
138
Standard Flow Cell 10 MM / 14 Μl
139
Micro Flow Cell, 5 MM / 1 Μl (Only for Support)
140
Micro Flow Cell 3 MM / 2 Μl
142
Semi-Micro Flow Cell 6 MM / 5 Μl
144
High Pressure Flow Cell 10 MM / 14 Μl
146
Cuvette Holder
148
Leak Parts
149
Kits
150
11 Identifying Cables
151
Cable Overview
152
Analog Cables
154
Remote Cables
156
BCD Cables
159
CAN/LAN Cables
161
RS-232 Cable Kit
162
External Contact Cable
163
12 Hardware Information
165
Firmware Description
166
Optional Interface Boards
169
Electrical Connections
172
Serial Number Information (ALL)
173
Rear View of the Module
174
Interfaces
175
Interfaces Overview
178
Setting the 8-Bit Configuration Switch (Without On-Board) LAN
182
Communication Settings for RS-232C
183
Special Settings
185
Instrument Layout
187
Early Maintenance Feedback (EMF)
188
EMF Counter
188
Using the EMF Counters
188
13 Appendix
191
General Safety Information
192
Batteries Information
195
Radio Interference
196
Sound Emission
197
UV Radiation
198
Solvent Information
199
Declaration of Conformity for HOX2 Filter
201
Agilent Technologies on Internet
202
Advertisement
Agilent Technologies G1314C VWD-SL User Manual (136 pages)
Variable Wavelength Detector
Brand:
Agilent Technologies
| Category:
Security Sensors
| Size: 3.26 MB
Table of Contents
Table of Contents
5
1 Introduction to the Variable Wavelength Detector
10
Introduction to the Detector
10
Optical System Overview
11
Flow Cell
12
Electrical Connections
15
Instrument Layout
17
Early Maintenance Feedback (EMF)
18
EMF Counter
18
Using the EMF Counters
18
2 Site Requirements and Specifications
21
2 Site Requirements and Specifications
22
Site Requirements
22
Physical Specifications
24
Performance Specifications
25
3 Installing the Detector
27
Unpacking the Detector
28
Optimizing the Stack Configuration
30
Installing the Detector
33
Flow Connections to the Detector
36
4 Using the Detector
40
Setting up an Analysis
40
Before Using the System
40
Requirements and Conditions
42
Optimization of the System
44
Preparing the HPLC System
45
Running the Sample and Verifying the Results
54
Special Settings of the Detector
55
Control Settings
55
Online Spectra
56
Scanning with the VWD
57
Analog Output Settings
59
Special Setpoints
60
Peakwidth Settings
61
Optimizing the Detector
63
5 How to Optimize the Detector
65
Optimizing the Detector Performance
66
Match the Flow Cell to the Column
66
Set the Detector Parameters
69
6 Troubleshooting and Diagnostics
71
Overview of the Detector's Indicators and Test Functions
72
Status Indicators
73
Power Supply Indicator
73
Detector Status Indicator
74
User Interfaces
75
Agilent LC Diagnostic Software
76
7 Maintenance and Repair
77
Introduction to Maintenance and Repair
78
Simple Repairs - Maintenance
78
Exchanging Internal Parts - Repair
78
Warnings and Cautions
79
Cleaning the Detector
80
Using the ESD Strap
81
8 Maintenance
83
Overview of Maintenance
84
Exchanging a Lamp
85
Exchanging a Flow Cell
87
Repairing the Flow Cells
90
Using the Cuvette Holder
94
Correcting Leaks
96
Replacing Leak Handling System Parts
97
Replacing the Interface Board
99
Replacing the Detector's Firmware
99
Tests & Calibrations
100
Intensity Test
101
Intensity Test
102
Wavelength Verification/Calibration
104
Holmium Oxide Test
105
9 Parts and Materials for Maintenance
109
Overview of Maintenance Parts
110
Standard Flow Cell
111
Micro Flow Cell
112
Semi-Micro Flow Cell
113
High Pressure Flow Cell
115
Cuvette Holder
116
Leak Parts
117
Accessory Kit
118
A Appendix
120
General Safety Information
120
Lithium Batteries Information
123
Radio Interference
124
Sound Emission
125
UV-Radiation
126
Solvent Information
127
Declaration of Conformity for HOX2 Filter
129
Agilent Technologies on Internet
130
Advertisement
Related Products
Agilent Technologies G1321A FLD
Agilent Technologies G1315B
Agilent Technologies G1365B
Agilent Technologies G1321A
Agilent Technologies G1314B VWD
Agilent Technologies G1314B
Agilent Technologies G1314E
Agilent Technologies G1314F
Agilent Technologies G1314D
Agilent Technologies G1563A
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL