Traffic Control; Storm Control - NETGEAR XS728T ProSAFE Software Administration Manual

28-port 10-gigabit l2+ smart switch
Hide thumbs Also See for XS728T ProSAFE:
Table of Contents

Advertisement

Field
Session Time
VLAN ID

Traffic Control

From the Traffic Control menu, you can configure MAC filters, storm control, port security,
and protected port settings.
The Traffic Control folder contains links to features described in the following sections:

Storm Control

Port Security
Protected Ports
Private VLAN
Storm Control
A broadcast storm is the result of an excessive number of broadcast messages
simultaneously transmitted across a network by a single port. Forwarded message
responses can overload network resources and cause the network to time out.
The switch measures separately the incoming packet rate for broadcast, multicast, and
unknown unicast packets per port and discards packets when the rate exceeds the defined
value. You enable storm control per interface by enabling storm control per packet type and
defining the rate at which the packets are transmitted.
Storm control is configured as a percent of the maximum port speed, which is 10Gbps for all
ports.
To configure storm control settings:
1.
Select Security > Traffic Control > Storm Control.
2.
Select the check box next to the port to configure.
Select multiple check boxes to apply the same setting to all selected ports. Select the
check box in the heading row to apply the same settings to all ports.
Storm control can be enabled and a threshold can be defined separately for the following
packet types:
Unknown Unicast. If the rate of unknown L2 unicast (destination lookup failure),
traffic ingressing on an interface increases beyond the configured threshold, the traffic
is dropped.
Multicast. If the rate of L2 multicast traffic ingressing on an interface increases
beyond the configured threshold, the traffic is dropped.
XS728T ProSAFE 28-Port 10-Gigabit L2+ Smart Switch
Security
Description
This field displays the time since the supplicant has
logged in seconds.
This field displays VLAN ID assigned by the
authenticator to the supplicant device.
129