Hardware Installation and Connection

2.1 Rack-mounting (UAG5100)

Use the following steps to mount the UAG on an EIA standard size, 19-inch rack or in a wiring closet
with other equipment using a rack-mounting kit. Make sure the rack will safely support the
combined weight of all the equipment it contains and that the position of the UAG does not make
the rack unstable or top-heavy. Take all necessary precautions to anchor the rack securely before
installing the unit.
Note: Leave 10 cm of clearance at the sides and 20 cm in the rear.
Use a #2 Phillips screwdriver to install the screws.
Note: Failure to use the proper screws may damage the unit.
Align one bracket with the holes on one side of the UAG and secure it with the included bracket
1
screws (smaller than the rack-mounting screws).
Attach the other bracket in a similar fashion.
2
After attaching both mounting brackets, position the UAG in the rack and up the bracket holes with
3
the rack holes. Secure the UAG to the rack with the rack-mounting screws.