Carefully note the location of the cable and the connection locations of the various plugs.
Either mark each plug and socket, or take a photograph with a digital camera.
 In the illustration above, you see the power module (3) and the positions of the optional lighting
circuit board (2), of the optional actuator module (1) and of the optional G-Trac sensor (4).
Pull the plug (1) out of the power module.
 Use a 4 mm Allen wrench to loosen both of the hexagon socket head screws (2).
 Remove the washers and the black intermediate pieces.
Remove the power module by pulling it backwards from the guides.
Replace the power module.
Refitting the power module:
Refit the parts in reverse order.
Plug all the plugs into their old positions.
Select the drive program as described in chapter 7.4.6.
If a new software version is available, update the drive program as described in chapter 7.5.