Invacare Storm4 Max Service Manual page 28

Hide thumbs Also See for Storm4 Max:
Table of Contents

Advertisement

SERVICE MANUAL
PROBLEM
Motors do
not run
Motor
makes
clicking
noise
Scraping
noise or
motor
blocked
Transmissi
on makes
clicking
noise
28
OTHER
POSSIBLE
SYMPTOMS
CAUSE
None
Bad connections Check all cabling.
Fuse burnt out
Batteries
defective
Cabling to power
module or
remote defective
Power module
defective
Corroded
Water, salt or
contacts
urine has
penetrated
None
Bearing
defective
Collector
defective
None
Bearing
defective
Transmission
defective
None
Transmission
defective
Drive wheel
loose
Invacare
SOLUTION
Documentation
See chapter 7.3.5.
Check cabling and
See chapters 7.3.5 and
replace fuse
7.3.4
Replace batteries
See chapter 7.3.2.
check cabling
See chapter 7.3.5.
Replace power
See chapter 7.4.2.
module
Check cabling,
See chapter 7.3.5.
replace if
necessary.
Replacing the
See chapter 7.19.1.
motor
Replacing the
See chapter 7.19.1
motor
Replacing the
See chapter 7.19.1.
motor
Replace
See chapter 7.19.1.
transmission.
Replace
See chapter 7.19.1.
transmission.
Tighten drive
See chapter 7.18.1.
wheel, secure
bolts with Loctite if
necessary
®
4