2
Workshop Manual Ed. 06-2011
SETTINGS AND ADJUSTMENTS
CR 125 2011 - WR 125 2011
Coolant replacement
-
Place the vehicle on a flat ground and in horizontal position.
1
-
Place a vessel of adequate capacity on the right side of the vehicle under
the water pump (1).
-
Loosen the exhaust screw (2) using an 8 mm wrench.
-
Slowly open the RH radiator cap (3) and let the liquid drain.
-
After drain, tighten the screw (2) replacing the aluminium sealing washer.
Avoid removing radiator cap when engine is hot, as coolant may
spout out and cause scalding.
Difficulties may arise in eliminating coolant from painted surfaces.
H02664
If this occurs, wash off with water.
3
H06988