1
Workshop Manual Ed. 06-2011
ELECTRICAL SYSTEM
CR 125 2011 - WR 125 2011
Checking generator stator windings resistance (CR)
H06932
The generator consists of a 12 V alternator with a power of 500 at 10.000 rpm,
positioned inside engine left side cover.
Measure across Red/White and Black/Red wires of the connector (1); correct
value is about 25,5
If resistance is outside the specified limits, replace the complete generator.
H06933
H06934
Generator performance
RPM
A D.C.
(typical)
1000
5,8
1500
9,0
2000
10,9
3000
10,0
4000
8,0
5000
5,9
6000
4,0
AT EACH ENGINE OVERHAUL, CLEAN FLYWHEEL ROTOR TO
REMOVE ANY DEBRIS CAPTURED BY THE MAGNETS.
M.8
.