7525-xxx
Toner cartridge contacts
1.
Remove the right cover assembly. See
Remove the waste toner bottle. See
2.
3.
Remove the imaging unit. See
Remove the rear cover. See
4.
Remove the rear screw (A) in the waste toner bottle sensor contact to allow access to the cable cover.
5.
Note: The waste toner bottle sensor contact does not need to be unplugged or removed.
Remove the four screws (B) securing the cable cover.
6.
Turn the printer on the left side.
7.
Remove the screw (C) securing the spring contacts.
8.
Release the tabs (D) on the spring contact to release the spring contacts.