Armature Coil
Inspect for continuity between each segment.
Inspect for continuity between each segment and the
armature shaft.
If there is no continuity between the segments or there is
continuity between the segments and shaft, replace the
armature assembly with a new one.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
Tester knob indication
Continuity set (
)
?
Bearing
Check the bearings for damage.
If any damage is found, replace the armature assembly
with a new one.
Oil Seal
Check the seal lip for damage.
If any damage is found, replace the housing end (inside).
Starter Relay Removal and Installation
Removal
1) Turn the ignition switch OFF.
2) Disconnect the battery (–) lead wire from the battery.
3) Remove the frame cover. Refer to "Exterior Parts
Removal and Installation in Section 9D (Page 9D-
14)".
4) Remove the starter relay cover (1) and disconnect
the starter relay coupler (2) .
5) Disconnect the starter motor lead wire (3) and
I823H1190008-01
battery (+) lead wire (4).
6) Remove the starter relay (5).
Installation
Install the starter relay in the reverse order of removal.
I823H1190033-01
I823H1190034-01
Starting System:
B815H21906005
2
1
5
4
3
1I-6