[II] Quantization Level Adjustment (VideoTD Level)
Use the target tracking function (TT) to adjust the level of the signal to be recognized as a target. If a small
value is set, even weak target signals will be input to the target detection circuit of the target tracking function.
However, many unnecessary signals are also input, which may cause unstable target acquisition or tracking. It
is important to set a value four or five greater than the value with which unnecessary signals are detected.
The quantization level is adjusted to an optimal value, so do not change it carelessly.
Do not change the set quantization level
carelessly. If the level deviates from the proper
value, the target acquisition and tracking
functions will deteriorate. Otherwise, this may
cause accidents.
Procedures
1. Open the Serviceman Menu.
2. Perform the following menu open procedure to open the target tracking
setting menu.
3. To change the quantization level of the automatic acquisition area,
Increase or decrease numerical value by Left-clicking the ▲ / ▼ button
for the Video TD Level.
4. To change the quantization level of tracking and manual acquisition,
Increase or decrease numerical value by Left-clicking the ▲ / ▼ button
for the Video High Level.
CAUTION
RADAR/TT Initial Setup
→ TT
7-22