Sharp MX-M264U Service Manual page 252

Sharp mx-m264u; mx-m264n; mx-m314u; mx-m314n; mx-m354u; mx-m354n office digital multifunctional system
Hide thumbs Also See for MX-M264U:
Table of Contents

Advertisement

Signal name
Name [Type]
SATA_TXP
HDD differential data output
+
SHPOS
Shifter HP sensor
SOCD
SPF open/close detection
SPED
Document sensor
SPFM*
SFP transport motor
SPM*
SPF paper feed motor
SPPD1
SPF transport sensor 1
SPPD2
SPF transport sensor 2
SPPD3
SPF transport sensor 3
SPPD4
SPF transport sensor 4
SPRS
Pressure release solenoid
SPWS
Document width sensor
SRRC
PS clutch
STMPS
Stamp solenoid
TC_DA
Transfer output adjustment
analog output
TCS
Toner sensor density
detection
TFD1
Paper exit tray paper sensor
TFD2
Second paper exit full
TFD3
Right paper exit full sensor
TH_RA
Temperature analog sensor
signal input
TH_UM
Fusing thermistor
temperature detection
(upper main)
TH_US
Fusing thermistor
temperature detection
(upper sub)
THV-REM/
THV(–) remote output
THVREM/
THV(+) remote output
TNMA
Toner motor A
TNMB
Toner motor B
/TRC_FIN
Finisher communication
TXD
RIC, PCI (main) send data
TxD_FIN
Finisher communication
TXD_PCI
PCI (sub) send data
TXD_PCU
ICU communication
TXD_PIC
ICU-PIC communication
VBUS
USB Device VBUS
VBUS
USB Host (Rear) VBUS
VBUS1
USB Host1 VBUS
VBUS3
USB Host3 VBUS
VBUS4
USB Host4 VBUS
/WH_CNT
Dehumidifying heater OFF
signal
Y1A
151 selector output
signal_2CS
Y1B
151 selector output
signal_3CS (Op)
Y2
151 selector output
signal_4CS (Op)
Function/Operation
HDD differential data output
+
Shifter HP detection
HP detection
SPF open/close detection
Document detection
Detection
SPF transport motor drive
SPF paper feed motor drive
Detects paper pass.
Detection
Detects paper pass.
Detection
Detects paper pass.
Detection
Detects paper pass.
Detection
Controls the pressure
release solenoid.
Detects document width.
Controls the PS clutch.
Controls the stamp solenoid.
Transfer output adjustment
analog output signal
Toner sensor density
detection
Paper detection signal
Paper full detection
Paper full detection
Full detection
Temperature detection
signal
Fusing thermistor signal
Fusing thermistor signal
Transfer bias (–) ON signal
Transfer bias (+) ON signal
Motor drive signal
Motor drive signal
Finisher communication
signal
RIC, PCI (main) send data
Finisher communication
signal
PCI (sub) send data
ICU-PCU communication
signal
ICU-PIC communication
signal
USB Device power supply
Power shutoff
USB Host (Rear) power
Power shutoff
supply
USB Host1 power supply
Power shutoff
USB Host3 power supply
Power shutoff
USB Host4 power supply
Power shutoff
Dehumidifying heater OFF
Dehumidifying
signal
relay OFF
151 selector output
signal_2CS
151 selector output
signal_3CS (Op)
151 selector output
signal_4CS (Op)
MX-M264U ELECTRICAL SECTION 13 – 25
Connector level
Connector
No.
"L"
"H"
CN22
CN28
Close
CN14
CN14
CN14
CN14
CN14
CN14
CN14
CN14
OFF
ON
CN14
CN14
OFF
ON
CN14
Stamp
CN14
CN13
CN18
Paper
CN12
provided
Full detection
CN3
CN1
CN19
CN21
CN21
High voltage
CN13
output ON
High voltage
CN13
output ON
CN15
CN15
CN7
CN12
CN7
CN5
CN10
CN10
Power supply
CN17
Power supply
CN18
Power supply
CN43
Power supply
CN43
Power supply
CN43
Dehumidifying
CN13
relay ON
CN14
CN14
CN14
Pin
PWB
NOTE
No.
name
2
MFPC
PWB
5
PCU
28
SCNcnt
27
SCNcnt
3, 4, 5,
SCNcnt
6, 7
8, 9,
SCNcnt
10, 11,
12
1
SCNcnt
2
SCNcnt
24
SCNcnt
22
SCNcnt
13
SCNcnt
17
SCNcnt
15
SCNcnt
14
SCNcnt
6
PCU
Analog
6
PCU
Analog
9
PCU
5
PCU
5
PCU
9
PCU
Analog
4
PCU
Analog
6
PCU
Analog
10
PCU
16
PCU
1
PCU
2
PCU
11
PCU
3
MFPC
PWB
1
PCU
6
MFPC
PWB
25
PCU
15
PCU
1
MFPC
PWB
1
MFPC
PWB
1
MFPC
PWB
6
MFPC
PWB
11
MFPC
PWB
5
PCU
25
PCU
12
PCU
14
PCU

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Mx-m264nMx-m314uMx-m354uMx-m354nMx-m314n

Table of Contents