Sharp MX-M264U Service Manual page 110

Sharp mx-m264u; mx-m264n; mx-m314u; mx-m314n; mx-m354u; mx-m354n office digital multifunctional system
Hide thumbs Also See for MX-M264U:
Table of Contents

Advertisement

Item/Display
T
HI_WARMUP_TIME
U
HI_WU_FM_ON_TMP
V
HI_WU_END_TIME
W
HI_WU_JOB_SET_TMP 1
X
HI_WARMUP_BORDER
Y
LO_WU_JOB_SET_TMP 1
Z
JOBEND_FUMON_TIME
AA
HI_WU_JOB_SET_TMP 2
AB
LO_WU_JOB_SET_TMP 2
Code descriptions
TH_UM
Fusing thermistor main (Front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
List of destination groups
Group
Group A
JAPAN
Group B
U. S. A
Group C
AB_B
Group D
CHINA
31cpm machine
Item/Display
A
HL_UM READY
B
HL_US READY
C
HL_UM PLAIN PAPER BW
D
HL_US PLAIN PAPER BW
E
WARMUP FUMON HL_UM T
F
WARMUP FUMOFF HL_UM T
G
WARMUP END TIME
H
HL_UM HEAVY PAPER
I
HL_US HEAVY PAPER
J
HL_UM OHP PAPER
K
HL_US OHP PAPER
L
HL_UM E-STAR
M
HL_US E-STAR
N
HL_UM PRE-JOB
O
HL_UM WARMUP_120L
P
HL_US WARMUP_120L
Q
LO_WARMUP_TIME
Content
R, S applying time (Timer from
completion of Ready)
FM prior rotation start TH_US
when Warm-Up at alpha C or
above
Warm-Up completion time when
Warm-Up at alpha C or above
Job enable TH_UM temperature 1
when Warm-Up at alpha C or
above
Threshold value alpha to which U -
W is applied
Job enable TH_UM temperature 1
when Warm-Up at alpha C or
below
After rotating time when a job is
completed
Job enable TH_UM temperature 2
when Warm-Up at alpha C or
above
Job enable TH_UM temperature 2
when Warm-Up at alpha C or
below
Destination
CANADA
INCH
EUROPE
U. K
Content
Ready standby TH_UM set value
Ready standby TH_US set value
Black-White plain paper TH_UM
set value
Black-White plain paper TH_US
set value
Fusing motor pre-rotation start
TH_US set value
Fusing motor previous rotation
complete time
Warm-up complete time
Heavy paper TH_UM set value
Heavy paper TH_US set value
OHP-TH_UM set value
OHP-TH_US set value
Preheating TH_UM set value
Preheating TH_US set value
TH_UM set value when recovery
from Warm-Up
TH_UM set value when Warm-Up
at 120C or below
TH_US set value when Warm-Up
at 120C or below
O, P applying time (Timer from
completion of Ready)
MX-M264U SIMULATION 6 – 36
Setting
Group A
Group B
range
SW-A
SW-B
SW-A
0 - 255
0
0
0
0 - 220
0
0
0
0 - 60
18
18
18
30 - 220
130
175
175
1 - 119
60
60
60
70 - 220
130
175
175
0 - 60
0
0
0
70 - 220
130
175
175
70 - 220
130
175
175
HL_UM
Heater lamp main (Heat roller for front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
AUS.
AB_A
Setting
Group A
Group B
range
SW-A
SW-B
SW-A
70 - 220
185
185
185
70 - 220
180
180
180
70 - 220
185
195
190
70 - 220
185
195
190
0 - 200
0
0
0
0 - 60
0
0
0
0 - 20
18
18
18
70 - 220
200
70 - 220
200
70 - 220
190
70 - 220
190
70 - 220
95
95
95
70 - 220
95
95
95
70 - 220
130
180
180
70 - 220
130
180
180
70 - 220
130
180
180
0 - 255
0
0
0
Default value
Group C
SW-B
SW-A
SW-B
SW-A
0
0
0
0
0
0
0
0
18
18
18
18
175
175
175
175
60
60
60
60
175
175
175
175
0
0
0
0
175
175
175
175
175
175
175
175
Default value
Group C
SW-B
SW-A
SW-B
SW-A
185
190
190
190
180
185
185
185
195
195
200
195
195
195
200
195
0
0
0
0
0
0
0
0
18
18
18
18
200
200
200
200
190
195
190
195
95
95
95
95
95
95
95
95
180
190
190
190
180
190
190
190
180
190
190
190
0
0
0
0
Group D
SW-B
0
0
18
175
60
175
0
175
175
Group D
SW-B
190
185
200
200
0
0
18
200
200
195
195
95
95
190
190
190
0

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Mx-m264nMx-m314uMx-m354uMx-m354nMx-m314n

Table of Contents