Sharp MX-M264U Service Manual page 118

Sharp mx-m264u; mx-m264n; mx-m314u; mx-m314n; mx-m354u; mx-m354n office digital multifunctional system
Hide thumbs Also See for MX-M264U:
Table of Contents

Advertisement

Mode
CPY/
2/2 (LD)
REF (TS_OFF)
PRN*
1
ALL (TS_OFF)
REF (TS_ON_C)
ALL (TS_ON_C)
MD_LD
MD_LD_ENV
OTHER
1/2
TN_TMP_AREA
(TN/TC/MD)
TN_TMP_DATA
TN_HUD_DATA
TC_TMP_AREA
TC_TMP_DATA
TC_HUD_DATA
MD_VG_AREA
MD_DV_LIFE_AREA
MD_ENV_AREA
MD_DUPLEX_COUNTER
MD_LD_AREA
MD_LD_ENV_AREA
2/2
DESTINATION
(CRUM/CNT)
MODEL TYPE
CRUM DEST_K
*1: The left of the correction amount indicates the execution result, and the right indicates the reference value.
Default values for each item
Mode
Item/Display
CPY/
REF (TS_OFF)
LD (CP)
PRN
LD (PRT)
ALL (TS_OFF)
LD (CP)
LD (PRT)
REF (TS_ON_C)
LD (CP)
LD (PRT)
ALL (TS_ON_C)
LD (CP)
LD (PRT)
Item/Display
Page number
(*: Correction
value)
Left
LD (CP)
Right
LD (PRT)
Left
LD (CP)
Right
LD (PRT)
Left
LD (CP)
Right
LD (PRT)
Left
LD (CP)
Right
LD (PRT)
Left
LD (CP)
Right
LD (PRT)
Left
LD (CP)
Right
LD (PRT)
***
***
***
***
***
***
***
***
***
***
***
***
Left
xx
xx
Right
xx
Default value
35cpm machine
31cpm machine
181
181
181
181
181
181
181
181
MX-M264U SIMULATION 6 – 44
Content
Laser power default value when TS is
OFF (CP/PRT)
Laser power value after addition or
subtraction of the correction amount
when TS is OFF (CP/PRT)
Laser power default value when TS is ON
(CP/PRT)
Laser power value after addition or
subtraction of the correction amount
when Copy TS is ON (CP/PRT)
Drum membrane decrease laser power
correction amount (CP/PRT)
Environment laser power correction
amount (CP/PRT)
Toner control display temperature/
humidity area
Toner control display temperature AD
value
Toner control display humidity AD value
Transfer display temperature/humidity
area
Transfer display temperature AD value
Transfer display humidity AD value
Membrane decrease drum traveling
distance area
Developer life area for process
Environment correction area
Duplex counter
Laser power area
Laser power environment area
Machine side management CRUM
destination
Model type of the machine
Crum destination
26cpm machine
163
145
163
145
163
145
163
145
163
145
163
145
163
145
163
145
Default
Display range
value
0 - 255
For default
values refer
0 - 255
to "Default
0 - 255
values for
0 - 255
each item".
0 - 255
0 - 255
0 - 255
0 - 255
–127 - +127
0
–127 - +127
0
–127 - +127
0
–127 - +127
0
1 - 8
4
0 - 1023
0
0 - 1023
0
1 - 8
4
0 - 1023
0
0 - 1023
0
1 - 15
1
0 - 15
1
1 - 8
1
0 - 300
0
0 - 15
1
0 - 8
4
0 - 1
0