Code descriptions
TH_UM
Fusing thermistor main (Front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
List of destination groups
Group
Group A
JAPAN
Group B
U. S. A
Group C
AB_B
Group D
CHINA
35cpm machine
Item
Display
A
HL_UM PLAIN PAPER BW
DUP
B
HL_US PLAIN PAPER BW
DUP
C
PLAIN PAPER BW DUP
APP CNT
D
HL_UM HEAVY PAPER BW
DUP
E
HL_US HEAVY PAPER BW
DUP
F
HEAVY PAPER BW DUP
APP CNT
Code descriptions
TH_UM
Fusing thermistor main (Front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
List of destination groups
Group
Group A
JAPAN
Group B
U. S. A
Group C
AB_B
Group D
CHINA
Destination
–
–
CANADA
INCH
EUROPE
U. K
–
–
Content
Black and white plain paper
duplex TH_UM set value
Black and white plain paper
duplex TH_US set value
Black and white plain paper
duplex applying number of sheets
Black and white heavy paper
duplex TH_UM set value
Black and white heavy paper
duplex TH_US set value
Black and white heavy paper
duplex applying number of sheets
Destination
–
–
CANADA
INCH
EUROPE
U. K
–
–
MX-M264U SIMULATION 6 – 40
HL_UM
Heater lamp main (Heat roller for front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
–
–
–
–
AUS.
AB_A
–
–
Default value (SW-A)
Setting
Group
Group
Group
range
A
B
C
70 - 220
195
195
195
70 - 220
195
195
195
0 - 255
0
0
0
70 - 220
195
195
195
70 - 220
195
195
195
0 - 255
0
0
0
HL_UM
Heater lamp main (Heat roller for front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
–
–
–
–
AUS.
AB_A
–
–
Default value (SW-B)
Group
Group
Group
Group
D
A
B
C
195
195
195
195
195
195
195
195
0
0
0
0
195
195
195
195
195
195
195
195
0
0
0
0
Group
D
195
195
0
195
195
0