Purpose
Adjustment/Setting/Operation data check
Function (Purpose) Used to import the SIM22-6 data to a USB
memory in the TEXT format.
Section
Operation/Procedure
1)
Insert the USB memory into the main unit.
2)
Select a kind of data to be imported.
3)
Press [EXECUTE] key, and press [YES] key.
Procedure 2) The selected data are imported.
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
56-11
Purpose
Data copy
Function (Purpose) Used to save the data in the SD card to the
HDD temporarily.
Section
Operation/Procedure
1)
Press [EXECUTE] key, and press [YES] key.
The data are saved temporarily to the HDD.
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
Error display
COMPLETE
WARNING
ERROR (HDD ACCESS ERROR)
ERROR (LOW LEVEL BLOCK
WRITE ERROR)
ERROR (LOW LEVEL BLOCK
READ ERROR)
ERROR (NO DATA ADJUSTMENT)
TROUBLE (U2-42)
56-12
Purpose
Data copy
Function (Purpose) Used to copy the SD card data saved tem-
porarily in the HDD with SIM56-11 to the
machine.
Section
Operation/Procedure
1)
Press [EXECUTE] key, and press [YES] key.
The set values are copied from the HDD to the SD card.
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
Error display
COMPLETE
WARNING
NO DATA
ERROR (EXPORT DATA ILLEGAL)
ERROR (LOW LEVEL BLOCK
READ ERROR)
ERROR (NO DATA ADJUSTMENT)
ERROR (SD ACCESS ERROR)
Content
Normal completion
HDD unmounting
HDD access disable
Low level block IO error: write
Low level block IO error: read
Inconsistent data
U2-42 occurrence
Content
Normal completion
SD/HDD unmounting
No data
Export data illegal
Low level block IO error: read
Inconsistent data (Error at the verify
check)
SD access error (File IO error)
MX-M264U SIMULATION 6 – 64
60
60-1
Purpose
Operation test/check
Function (Purpose) Used to check the memory operations
(read/write) of the MFP PWB.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
Start the test.
Result display
OK
Success
NG
Fail
NONE
Not installed (Including DIMM trouble)
INVALID
Execution disable
SLOT
Description
ICU SLOT-1
ICU standard memory
ICU SLOT-2
ICU expansion memory
PCL SLOT-1
Printer standard memory
PCL SLOT-2
Printer expansion memory
ACRE SLOT
Enhanced compression kit memory
61
61-1
Purpose
Operation test/check
Function (Purpose) Used to check the LSU polygon motor rota-
tion and laser detection.
Section
LSU
Operation/Procedure
1)
Press [EXECUTE] key.
When the operation is completed normally, [OK] is displayed.
In case of an abnormal end, [NG] is displayed.
Display
LSU TESTRESULT NG: PG
LSU TESTRESULT NG: K
Description
DIMM1
DIMM2
DIMM3
DIMM4
-
Content
Polygon mirror rotation abnormality
Laser abnormality (K)