50-2
Purpose
Adjustment
Function (Purpose) Used to adjust the copy image position and
the image loss. (This simulation is a simpli-
fied version of SIM 50-1.)
Section
Operation/Procedure
1)
Set item A (L1) and item B (L2) to 0.
2)
Place a rule on the left edge of the document table, and make
a copy at a magnification ratio of 400%.
3)
Measure the length of L1 and L2 on the copied image in the
unit of 0.1mm (referring to the figure below). Enter the adjust-
ment values of L1 x 10 and L2 x 10. Be sure to enter the both
adjustment values of L1 and L2.
L1: Distance from the lead edge of the copied image to 10mm
scale.
L2: Distance from the paper lead edge to the copy image lead
edge.
Paper lead
edge
L2
4)
Press [EXECUTE] key. (The set value is saved.)
5)
Make a copy at the magnification ratio of 100%, and adjust the
rear edge void.
Item/Display
A
Actual
L1
Distance from the
measurem
image lead edge to
ent value
the scale of 10mm.
(Platen 400%, 0.1mm
increment)
B
L2
Distance from the
paper lead edge to the
image lead edge
(0.1mm increment)
C
Image loss
LEAD
Lead edge image loss
area
amount setting (When
setting
the adjustment value
value
is increased, the
image loss is
increased.)
D
SIDE
Side edge image loss
amount setting (When
the adjustment value
is increased, the
image loss is
increased.)
L1
400% enlargement copy
Fig. 1
Setting
Default
Description
range
value
0 - 999
0 - 999
0 - 99
0 - 99
MX-M264U SIMULATION 6 – 55
Item/Display
E
Void area
adjustment
F
G
Same as the adjusted items of SIM50-01 except for A and B.
The values adjusted with A and B are reflected to the document
lead edge reference position (RRC-A) of SIM50-01 and all the
paper lead edge positions (RRCB-**).
All adjustment items: 1 step = 0.1mm change
-
0
40
20
Description
DENA
Lead edge void area
adjustment (When the
adjustment value is
increased, the void is
increased.)
DENB
Rear edge void area
adjustment (When the
adjustment value is
increased, the void is
increased.)
FRONT/
FRONT/REAR void
REAR
amount adjustment
(When the adjustment
value is increased, the
void is increased.)
Setting
Default
range
value
1 - 99
30
1 - 99
30
1 - 99
20