(2) Remove 1 E-ring and take off the cam.
(3) Move the shaft of the separation finger toward
the rear side and pull it out.
(4) Remove the screws and pull out the
separation fingers from the shaft.
[G] Image quality sensor
(1) Remove 2 screws and take off the sensor with
the bracket.
(2) Remove 2 screws and take off the image
quality sensor.
JUNE 2002 © TOSHIBA TEC
11 - 9
e-STUDIO550/650/810 CLEANER UNIT
E-ring
Cam
Separation finger
Connector