5.23.3 Connecting the gas supply

B Make the gas connection in accordance with all locally
applicable regulations.
B Connect the gas pipe without stress to the gas
connector.
B Install a gas shut-off valve in the gas supply pipe.
We recommend that a gas filter be installed
in the pipework in accordance with local
regulations.
B Before initial start-up, check for external leakage on the
new length of piping up to the gas valve.
B If a leak is discovered, all connections must be
checked using a frothing agent.
DANGER: Risk to life from gas explosion!
Leaks may have been created on pipes and
fittings following the commissioning work.
B Carry out the correct leak tests.
B Only use approved leak detection agents
for leak detection.
CAUTION: Risk of system damage due to
short circuit!
B Cover areas at risk prior to carrying out a
leak test.
B Do not spray the leak solution on wiring
openings, plugs or electrical connections.
Do not allow it to drip onto them either.