Retransmission At The Time Of Soap Transmission Error; E-Rds Setting Screen - Canon iR2030 Series Service Manual

Ir2030/2025/2022/2018 series
Hide thumbs Also See for iR2030 Series:
Table of Contents

Advertisement

Transmission Detail / Process Detail
Operation list check
getOperationList
Schedule information update
getConfiguration
Environment log (Device condition log) transmission
postEnvironmentLog
Alert filtering
getAlertCodeNotificationList
- The timing of transmission to UGW varies according to the device.
- The timing of transmission to UGW cannot be set on the side of the device.

10.1.8 Retransmission at the time of SOAP Transmission Error

iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
In case the SOAP transmission error occurs due to the fault at UGW side at the time of the alert code transmission, store the last 3 data failed to transmit in the
RAMDISK, and retransmit it with the predefined intervals.
In addition, in case the SOAP transmission error occurs at the time of the jam log or service call log transmission, retransmit the data failed to transmit with the
predefined intervals. (When transmitting these 2 types of data, RAMDISK is not used, and the number of retransmission is not restricted.)

10.1.9 e-RDS Setting Screen

iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
(1). Setting Items
The forms and default values of the setting items related to the e-RDS in the service mode are as follow:
Service Mode
Setting Items (Meaning)
E-RDS SWITCH
RGW-ADDRESS
(RDS-Gateway ADDRESS)
RGW-PORT
(RDS-Gateway PORT)
COM-TEST
(Communication Test)
COM-LOG
(Communication Log)
(2). Screen Menu
Transmission Timing
Once every 16 hours.
Upon a request from UGW
At the time of communication test
Once every 12 hours.
Upon a request from UGW
T-10-2
e-RDS OFF/ON 0: OFF/1: ON
When the setting is ON, transmit the counter information and error information to UGW.
Default value: 0 (OFF)
URL of UGW
Default value: the actual URL of UGW
Number of characters: 129 bytes (Including NULL. 1-byte code only)
Port number of UGW
Default value: 443
Setting range: 1 to 65535
Execution of communication test
Judge whether the connection with UGW is established, and display the result with either 'COM-TEST OK' or
'COM-TEST NG'.
Detail of the communication test result
Display the error log for the communication with UGW.
As the error information, occurred time, error code, and error detail information are displayed.
Max. number of log: 5
Error information: max. 128 characters (Excluding NULL)
Remarks
The environment information inside the
device such as temperature and humidity.
When requested from UGW with
'getOperationList'
Description
Chapter 10
0017-6741
0017-6742
10-3