Chapter 8

8.4 Parts Replacement Procedure

8.4.1 Fixing Unit

8.4.1.1 Removing the Fixing Unit

iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
1) Draw out the drum unit.
2) Detach the rear cover.
3) detach the left cover (rear).
4) Disconnect the connector [1] of the junction harness and remove the reus-
able band [2], then remove the earth wire [3].
- Screw [4], 1 pc.
[2]
5) Remove the screw [1] securing the door support band. Remove the con-
nector [2] and reusable band [3], and release the duplex unit harness from
the wire saddle [4].
[2]
8-8
[3]
[4]
[1]
F-8-6
[1]
[3]
[4]
F-8-7
6) Open the left door until it sops and pull out the hinge shaft [1].
0017-8159
[1]
7) Lift the left door with both hands to release it from the door rotation shaft
[1], and then remove the left door.
[1]
8) Detach the inner cover [1] at the upper front.
- Screw [2], 2 pcs.
F-8-8
F-8-9
[2]
[1]
[2]
F-8-10