4.1.3 Removing the Fixing Assembly

1) Remove the riser guide. (p. 6-12P)
2) Check to see if the feeding assembly is
locked in position.
3) Disconnect the three connectors [1].
4) Remove the two screws [2], and detach
the fixing assembly [3].

4.1.4 Removing the Fixing Stepped Gear

1) Remove the fixing assembly. (See item
4.1.3.)
2) Remove the E-ring [1], and detach the
gear [2].
3) Free the claw, and detach the fixing
stepped gear [3].

4.1.5 Removing the Fixing Film Unit

1) Remove the fixing assembly. (See item
4.1.3.)
2) Remove the screw [1], and slide the in-
let upper guide [2] to the rear to re-
move.
3) Remove the screw [3], and detach the
sensor unit [4] and the sensor unit guide
[5].