4.1.3 Removing the Fixing Assembly
1) Remove the riser guide. (p. 6-12P)
2) Check to see if the feeding assembly is
locked in position.
3) Disconnect the three connectors [1].
4) Remove the two screws [2], and detach
the fixing assembly [3].
4.1.4 Removing the Fixing Stepped Gear
1) Remove the fixing assembly. (See item
4.1.3.)
2) Remove the E-ring [1], and detach the
gear [2].
3) Free the claw, and detach the fixing
stepped gear [3].
4.1.5 Removing the Fixing Film Unit
1) Remove the fixing assembly. (See item
4.1.3.)
2) Remove the screw [1], and slide the in-
let upper guide [2] to the rear to re-
move.
3) Remove the screw [3], and detach the
sensor unit [4] and the sensor unit guide
[5].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 FIXING SYSTEM
[1]
[2]
[3]
F06-401-04
[3]
F06-401-05
[2]
F06-401-06
[2]
[2]
[1]
[5]
[3]
[4]
[1]
6-13 P