E019
Indicates that the waste toner case is full.
The waste toner case can hold waste toner equivalent of about 200,000
prints.
Memo
8.3 Locking of the Waste Toner Feedscrew
The waste toner feedscrew is rotated by the drive of the main motor transmitted by the
coupling built into the main motor drive assembly. The coupling is butted against the gear
used to rotate the screw by the work of a spring.
If the drum cleaning assembly is clogged with waste toner, the coupling will start to move
back and forth in the axial direction, causing a clicking sound.
The machine is not equipped with a sensor to detect the locking of the
waste toner feedscrew.
Memo
Main motor
M1
Spring
COPYRIGHT © 2001 CANON INC.
Coupling
F04-803-01
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 4 IMAGE FORMATION SYSTEM
Photosensitive drum
Waste toner feedscrew
4-25 P