6 Replacing the Drum Unit

Work
1) Turn off the main power switch; then,
open the front cover.
2) Shift the feeding assembly releasing le-
ver to free the feeding assembly.
3) Turn the developing assembly locking
lever counterclockwise to free the de-
veloping assembly.
4) Remove the fixing screw from the drum
unit.
(The removed fixing screw will be used
when mounting the new drum unit.)
5) Pull the drum unit straight out to the
front.
6) Unpack the new drum unit, and detach
the two releasing members of the pri-
mary charging roller.
1. Do not touch the drum area to
avoid scratching the photo-
sensitive drum.
2. Do not expose the photosen-
sitive drum to strong light.
3. Take care not to damage the
stirs found on the bottom of
the drum unit.
4. When removing the tape from
the rear end of the drum unit,
keep the rear end higher than
the front cover to prevent
spilling waste toner.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 3 INSTALLATION
Checks/remarks
Tape
Primary charging roller
releasing members
3-27 S