Processing Tab

The Processing tab contains a user configurable key delay that applies to scanned bar codes as they are input when Remote
Desktop is the application with the input focus.
Setting
Same buffer limit
Delay between buffers
Only in Remote Desktop
Note: Settings on this panel have no effect when RFTerm is the application with the input focus.
Enable buffered key output
This option cannot be changed.
Same buffer limit
Specifies the maximum number of characters that the platform and network environment can process correctly without losing
data. The default is 32.
Delay between buffers
Specifies the number of milliseconds to delay after each character in the scanned bar code is processed as a keystroke. This
value may need to be adjusted depending on the network traffic in the environment. The default value is 75 ms. Valid value is
from 0 to 9999. A zero value is No Delay between characters.
Only in Remote Desktop
The delay specified in Delay between buffers is only applied when Remote Desktop is enabled and is the application with the
input focus. When disabled, all keystrokes are delayed by the number of milliseconds specified in Delay between buffers.
Default
32
75 ms
Enabled