Epson AcuLaser C9200N Service Manual page 173

A3 color laser printer
Hide thumbs Also See for AcuLaser C9200N:
Table of Contents

Advertisement

EPSON AcuLaser C9200N
[4]
5. Snap off the C-clip [4], one collar [5] and remove the Feed Roller [6].
When installing the Feed Roller with a new one, make sure to reset the life counter.
A D J U S T M E N T
R E Q U I R E D
(Refer to Chapter 5 "ADJUSTMENT") (p313))
DISASSEMBLY AND ASSEMBLY
[6]
[5]
Main Unit Disassembly/Reassembly
E1
The pickup roller should be replaced, whenever the separation roller is replaced.
C H E C K
P O I N T
1. Slide out the standard paper cassette.
2. Remove two Screws [1] and the Separation Roller ounting bracket assy [2].
Revision D
Separation Roller (Standard Cassette)
[2]
[1]
4038F2C002DB