EPSON AcuLaser C9200N
E400: ABNORMALLY LOW TONER DENSITY DETECTED CYAN
TCR SENSOR
E402: ABNORMALLY LOW TONER DENSITY DETECTED
MAGENTA TCR SENSOR
E404: ABNORMALLY LOW TONER DENSITY DETECTED
YELLOW TCR SENSOR
Relevant Electrical Parts
Photoconductor Unit/C
Photoconductor Unit/M
Photoconductor Unit/Y
Toner Supply Motor Y/M (M6)
Step
Action
1
Perform image
troubleshooting procedure if
image density is low.
2
Clean the TCR Sensor
window on the underside of
the Photoconductor Unit if
dirty.
3
M6, M7 operation check
4
Reinstall Photoconductor
Unit.
5
Change Photoconductor Unit.
6
Change PWB-M
(p.198)
7
Change PWB-P
(p.198)
Troubleshooting
Toner Supply Motor C/K (M7)
Mechanical Control Board (PWB-M)
Controller Board (PWB-P)
Connection Diagram
Location
Control Signal
(electrical parts)
---
---
PWB-M CNDM2-10 to 13(M6)
PWB-M CNDM3-10 to 13(M7)
---
---
---
---
E401: ABNORMALLY HIGH TONER DENSITY DETECTED CYAN
TCR SENSOR
E403: ABNORMALLY HIGH TONER DENSITY DETECTED
MAGENTA TCR SENSOR
E405: ABNORMALLY HIGH TONER DENSITY DETECTED
YELLOW TCR SENSOR
Photoconductor Unit/C
Photoconductor Unit/M
Photoconductor Unit/Y
Step
1
Clean the TCR Sensor window on the
underside of the Photoconductor Unit if
---
dirty.
2
Reinstall Photoconductor Unit.
---
3
Change Photoconductor Unit.
4
Change PWB-M
5
Change PWB-P
C-22
C-23
---
---
---
---
Service Call Error
Relevant Electrical Parts
Mechanical Control Board (PWB-M)
Controller Board (PWB-P)
Connection Diagram
Action
Control Signal
---
---
---
(p.198)
---
(p.198)
---
Revision D