Gradation Reproduction Failure; Abcd; Monocolor> Foggy Background - Epson AcuLaser C9200N Service Manual

A3 color laser printer
Hide thumbs Also See for AcuLaser C9200N:
Table of Contents

Advertisement

EPSON AcuLaser C9200N
<MONOCOLOR>

GRADATION REPRODUCTION FAILURE

A. Typical Faulty Images
4036fs4048c0
B. Troubleshooting Procedure
Step
Section
Check Item
1
Photoconductor
Dirty on the outside.
Unit
2
PH Unit
The surface of the PH
Window is dirty.
3
TCR Sensor
TCR Sensor window is dirty.
window
4
Adjust Density Change the setting value for
"Max Density" in the Printer
Adjust Menu.
5
The problem has been
eliminated through the checks
of steps up to 5.
Troubleshooting
4036fs4049c0
Result
Action
YES
Clean.
YES
Clean with cleaning jig.
YES
Clean.
NO
Go to next step.
NO
Change Photoconductor Unit.
Change Controller Board.
(p.198)
Change PH Unit.
(p.175)
Change High Voltage Unit
(Image Transfer,
Neutralizing).
(p.230)
Image quality problem
<MONOCOLOR>
FOGGY BACKGROUND
A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
Check Item
1
Photoconductor
Dirty on the outside.
Unit
2
PH Unit
The surface of the PH
Window is dirty.
3
TCR Sensor
The color TCR Sensor
window
window is dirty.
4
Adjust Density Change the setting value for
"Max Density" in the Printer
Adjust Menu.
5
Blur Margin
Change the setting value for
"Blur Margin" in the Printer
Adjust Menu.
6
The problem has been
eliminated through the checks
of steps up to 5.
Revision D

ABCD

ABCD
ABCD
ABCD
ABCD
4036fs4030c0
Result
Action
YES
Clean.
YES
Clean with cleaning jig.
YES
Clean.
NO
Go to next step.
NO
Go to next step.
NO
Change Photoconductor Unit.
Change Controller Board.
(p.198)
Change PH Unit.
Change High Voltage Unit
(Image Transfer,
Neutralizing).
(p.230)
Confidential
(p.175)
142

Hide quick links:

Advertisement

Table of Contents
loading