JRC JMA-7710-6 Instruction Manual page 120

Hide thumbs Also See for JMA-7710-6:
Table of Contents

Advertisement

3.3
Example :
If it is assumed that the maximum range of the initial PM pattern, rBmax, recorded in the
Information Label is 16 NM and the maximum range of the current PM pattern, rAmax, is 14
NM, the value of decrease,
shows that the sensitivity of the receiving system has lowered by approx. 5 dB.
Example of checking the receiving system
P.M.FORM
dB
16
14
12
R(14)
10
8
∆r
6
R(16)
4
2
0
0
12
r(max) = 5 dB, can be obtained from calibration curve II, which
16NM
P.M.FORM
Calibration Curve II
13
14
15
16
17
rAmax
rBmax
Maximum range of PM pattern, r max
3 – 61
ABOUT 14NM
PERF. MONITOR
INFORMATION LABEL
DATE
P. MON
'95 1/20
18(NM)
8.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-7725-6Jma-7725-9