Tightening torque (unit: DAN.M)
Energy storage
High-pressure pipeline coupler
Lifting ring fixing nut
Remarks:
Before maintaining the entire automated mechanical
transmission, use a special repair tool to remove the
energy storage (refer to the section of "ENERGY
STORAGE").
Removal:
Remove the battery.
Use the injector to evacuate the oil tank.
Remove:
- Low-pressure pipeline
- High-pressure pipeline
- Transmission housing mounting bracket
- Energy storage
- Oil tank fixing bolts (A)
Disconnect the clutch cable.
Remove the electronic injection computer.
Remove:
- High-pressure pipeline
- Low-pressure pipeline
- Connectors
- Fasteners on the transmission housing
- Energy storage
- Three fixing bolts for electric pump set
PDF created with pdfFactory Pro trial version
CHERY SQR7080 EZ Drive SERVICE MANUAL
MECHANICAL TRANSMISSION – OIL TANK
4
1.4
2.1
www.pdffactory.com
A: suck in
B: flow back
Remounting:
Carry out the remounting procedure that is opposite
to the removal procedure.
Fill the ELF RENAULT MATIC D3 SYN
DEXRON oil to the degree that the oil level is 32 to
38 mm higher than the lowest mark line.
Perform the corresponding test by using a special
tool. (Refer to the page 21-36 of section "special
requirements on change of system parts and
components of KIT electrically controlled hydraulic
system").
Oil filling into oil tank
The mark shown on the oil tank is the lowest
standard.
Carry out the energy storage removal procedure.
Make sure that the oil level is 32 to 38mm higher
than the lowest mark line.
Important tip:
The oil level will be at the position indicated by the
mark line (MIN) when the energy storage has been
fully inflated (15 seconds after ignition).