Connecting Power; Connecting Ac Power - Juniper J2300 Getting Started Manual

Services router
Hide thumbs Also See for J2300:
Table of Contents

Advertisement

J2300, J4300, and J6300 Services Router Getting Started Guide
plug cord, a threaded insert (PEM nut), screw, and washer are provided on
the rear of the chassis to connect the router to earth ground.
CAUTION: Before router installation begins, a licensed electrician must attach a
cable lug to the grounding and power cables that you supply. A cable with an
incorrectly attached lug can damage the router (for example, by causing a short
circuit).
The grounding cables must be 14 AWG single-strand wire cable, and must be
able to handle the following amperage:
Each grounding lug must be a ring-type, vinyl-insulated TV14-6R lug, or
equivalent, to accommodate the 14 AWG cable.
To ground the router before connecting power, you connect the grounding cable
to earth ground and then attach the lug on the cable to the chassis grounding
point, with the screw. (See "Connecting Power" on page 102.)

Connecting Power

J2300 or J4300 Services Routers have a single fixed power supply. J6300
Services Routers have one or two field-replaceable power supplies. For more
information about the J-series power specifications, see "Power Guidelines,
Requirements, and Specifications" on page 89.
WARNING: DC-powered J2300 Services Routers are intended for installation in a
dedicated equipment room where they are accessible by trained personnel only.
DC-powered Services Routers are intended for installation only in a restricted
access location.

Connecting AC Power

The router must be connected to earth ground during normal operation. The
protective earthing terminal on the rear of the chassis is provided to connect
the router to ground. Additional grounding is provided to an AC-powered router
when you plug its power supply into a grounded AC power receptacle.
The AC power cord shipped with the router connects the router to earth ground
when plugged into an AC grounding-type power outlet. The router must be
connected to earth ground during normal operation.
102
Connecting Power
J2300 router—up to 4 A
J4300 router and J6300 router—up to 8 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

J4300J6300

Table of Contents