Maintenance

Troubleshooting Guide

POSSIBLE CAUSE(S)
SYMPTOM: Oven will not fire.
Gas turned off.
S
Oven not plugged in.
S
Power switch on the control panel is off.
S
Control set below ambient temperature.
S
Doors are open.
S
Computerized controls --- error code on display.
S
SYMPTOM: Oven does not come to ready.
The oven has not reached preheat temperature.
S
Gas valve not turned on completely.
S
The quick disconnect is not connected.
S
Gas pressure to oven is too low.
S
Fan delay feature may be activated, if applicable.
S
Internal problem with main temperature control.
S
SYMPTOM: Convection fan does not run.
Oven is not plugged in.
S
Oven is not set to the cook mode.
S
Circuit breaker tripped.
S
Fan delay feature may be activated, if applicable.
S
Doors are open
S
SYMPTOM: General baking problems.
Computerized controls --- incorrect product
S
programming.
Thermostat out of calibration.
S
Improper oven venting.
S
*Denotes remedy is a difficult operation and should be performed by qualified personnel only. It is recommended, however, that
All repairs and/or adjustments be done by your local Blodgett service agency and not by the owner/operator. Blodgett cannot as-
sume responsibility for damage as a result of servicing done by unqualified personnel.
WARNING!!
Always disconnect the power supply before cleaning or servicing the oven.
SUGGESTED REMEDY
Turn the gas valve to ON.
S
Plug in electrical supply cord.
S
Set the control panel to COOK or OVEN ON.
S
Set to desired cook temperature.
S
Close doors.
S
*
S
Wait for oven to reach preheat temperature.
S
Check the gas valve, turn on fully if necessary.
S
Reconnect the quick connect. Check all gas
S
connections.
Call your local gas representative.
S
Deactivate fan delay feature.
S
*
S
Plug in electrical supply cord.
S
Set the control panel to COOK or OVEN ON.
S
Reset the breaker.
S
Deactivate fan delay feature.
S
Close doors.
S
Reprogram control per Operation section.
S
*
S
*
S
38