MANAGER LEVEL PROGRAMMING
Entering the programming mode
1. Press the PROG KEY (10). The top display
reads CodE.
2. Use the product keys to enter the program-
ming access code: 4 5 1 2. Press the ENTER
KEY (14). The top display reads SYS.
Programming hold
Hold allows product to be kept warm in the oven
at a programmed time and temperature.
1. Press the SCAN KEY (15). The top display
reads Hold. Press the TOGGLE/CLEAR KEY
(11) to toggle between YES and no. Press the
SCAN KEY (15).
If no is chosen:
a.. Press the SCAN KEY (15) to advance to pro-
gramming the setback mode.
If yes is chosen:
a.. The top display reads HOLD. The bottom
display gives the current hold time. Press
the TOGGLE/CLEAR KEY (11). Use the
product keys to enter a hold time from 0
to 9 hours. Press the SCAN KEY (15) to
enter the new hold time (HR:MN).
b.. The top display reads HOLD. The bottom
display gives the current hold tempera-
ture. Press the TOGGLE/CLEAR KEY (11).
Use the product keys to enter a hold tem-
perature from 140_F---210_F. Press the
SCAN KEY (15) to enter the new hold tem-
perature.
c.. The top display reads FAn. The bottom
display gives the current fan mode. To
change the fan mode press the TOGGLE/
CLEAR KEY (11). The bottom display
toggles between Hi and Lo. Press the
SCAN KEY (15) to enter the new fan mode
and continue with programming the set-
back mode.
Programming the setback mode
The setback mode operates as a power saving fea-
ture. After a period of non-use (the setback time) the
oven temperature automatically decreases to the
setback temperature. The oven will maintain this
temperature until a product key is pressed.
1. The top display reads SEtb. The bottom dis-
play gives the setback mode. To change the
setback press the TOGGLE/CLEAR KEY (11).
The bottom display toggles between YES and
no. Press the SCAN KEY (15).
If no is chosen:
a.. The controller advances to programming
the temperature mode.
If yes is chosen:
a.. The bottom display gives the current set-
back time. Press the TOGGLE/CLEAR KEY
(11). Use the product keys to the enter the
desired setback time. Press the SCAN KEY
(15) to enter the new setback time.
NOTE: The minimum setback time is 20:00.
The maximum setback time is 59:59.
b.. The bottom display gives the current set-
back temperature. Press the TOGGLE/
CLEAR KEY (11). Use the product keys to
the enter a setback temperature from
140_F---300_F. Press the SCAN KEY (15) to
enter the new setback and continue with
programming the temperature mode.
33
Operation
Blodgett IQ2T Control