Blodgett DFG-100 XCEL Installation And Operation Manual page 15

Table of Contents

Advertisement

Available languages

Available languages

PRESSURE REGULATION AND TESTING
DFG-100 X
ovens are rated at 60,000 BTU/Hr.
CEL
(17.5 kW) (63 MJ) per section at standard rate or
80,000 BTU/Hr. (23.5 kW) (84 MJ) per section at
high rate. Each oven has been adjusted at the fac-
tory to operate with the type of gas specified on the
rating plate.
Inlet Pressure
Natural
Min
Max
W.C.
7.0"
10.5"
kPa
1.742
2.61
Manifold Pressure
Natural
W.C.
2.0"
3.5"
kPa
0.50
Inlet Pressure --- the pressure of the gas before
D
it reaches the oven.
Manifold Pressure --- the pressure of the gas
D
as it enters the main burner(s).
Min --- the minimum pressure recommended to
D
operate the oven.
Max --- the maximum pressure at which the
D
manufacturer warrants the oven's operation.
Gas Connection 3" (76 mm)
Propane
Min
Max
11.0"
13.0"
2.74
3.23
Propane
5.5"
10.0"
.87
1.37
2.49
Each oven is supplied with a regulator to maintain
the proper gas pressure. The regulator is essen-
tial to the proper operation of the oven and
should not be removed. It is preset to provide the
oven with 2.0 and 3.5" W.C. (0.50 and 0.87 kPa) for
natural gas and 5.5 and 10.0" W.C. (1.37 and 2.50
kPa) for Propane at the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS
SUPPLY UNLESS THE INLET PRESSURE IS
ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be
thoroughly purged of all metal filings, shavings,
pipe dope, and other debris. After connection, the
oven should be checked for correct gas pressure.
The oven and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (13.85" W.C., 3.45
kPa).
The oven must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas piping system at test pressures equal or less
than 1/2 psig (13.85" W.C., 3.45 kPa).
Gas Connection 3.75" (86 mm)
Figure 9
11
Installation
Gas Connection

Hide quick links:

Advertisement

Table of Contents
loading