Step 1540-17
The system is working correctly with this configuration. One of the FRUs (adapters)
that you removed is probably defective.
1. Turn the power off and remove the power cable.
2. Install a FRU (adapter) and connect any cables and devices that were attached
to it.
Note: If the FRU you installed requires supplemental media use the Process
Supplemental Media task to load the supplemental media first.
3. Plug in the power cable and wait for OK on the operator panel display.
4. Turn the power on.
5. If the Console Selection screen is displayed, choose the system console.
6. After the keyboard indicator is displayed, press the F5 key on the directly-
attached keyboard or the number 5 key on an ASCII terminal keyboard.
7. Enter the appropriate password if prompted to do so.
Is the "Please define the System Console" screen displayed?
NO
Go to "Step 1540-18" on page 2-56.
YES
Repeat this step until all of the FRUs (adapters) are installed.
Go to "Map 0410: Repair Checkout" in the Diagnostic Information for Mul-
tiple Bus Systems.
Chapter 2. Maintenance Analysis Procedures
2-55