Table 3-1 (Page 27 of 40). Firmware Error Codes.
Error Code
Description
40111042
A high 2.5 voltage reading detected
A high +12 voltage reading detected
40111052
A high −12 voltage reading detected
40111062
40111072
A high +5 standby voltage reading
detected
40111082
A low 5.0 voltage reading detected
3-28
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
1. Remove processor card in processor
card connector #2 (if installed) and
see if the problem is resolved. If
problem is resolved replace processor
card. If not, continue.
2. Exchange processor card in processor
card connector #1 with the processor
card removed in step 1 (or replace
processor card if only one processor
card exists) and see if problem is
resolved. If problem is resolved
replace processor card. If not, con-
tinue.
3. Power supply.
1. Power supply.
2. I/O board (See notes on 3-1.)
1. Power supply.
2. I/O board (See notes on 3-1.)
1. Remove processor card in processor
card connector #2 (if installed) and
see if the problem is resolved. If
problem is resolved replace processor
card. If not, continue.
2. Exchange processor card in processor
card connector #1 with the processor
card removed in step 1 (or replace
processor card if only one processor
card exists) and see if problem is
resolved. If problem is resolved
replace processor card. If not, con-
tinue.
3. Power supply.
1. Power supply.
2. Remove processor card in processor
card connector #2 (if installed) and
see if the problem is resolved. If
problem is resolved replace processor
card. If not, continue.
3. Exchange processor card in processor
card connector #1 with the processor
card removed in step 1 (or replace
processor card if only one processor
card exists) and see if problem is
resolved. If problem is resolved
replace processor card.