IBM H Series Installation And Service Manual page 141

Enterprise server
Table of Contents

Advertisement

Table 3-1 (Page 32 of 40). Firmware Error Codes.
Error Code
Description
40D00101
Bist on I/O board failed
40D00102
BIST on system board fail
45800000
Memory controller checkstop
45B00001
A non-compatible memory card is
detected
45C00000
Memory checkstop. (Uncorrectable
memory error.)
48800909
System vpd error
4880090A
Generic vpd error
4880090B
Error identifying system type using
vpd
4880090C
Jtag unable to confirm system type
using system vpd
Action / Possible Failing FRU
I/O board (See notes on 3-1.)
System board.
1. System board.
2. If problem is not resolved continue to
"Step 1540-25" on page 2-61.
Replace the memory card, as indicated by
the physical location code, with a compat-
ible memory card supported by this
system.
1. Attempt to reboot the system in
Service Mode. This preserves the AIX
error log. If the reboot fails, attempt to
reboot from the CD-ROM. If the reboot
is successful, run Diagnostics in
Problem Determination mode to deter-
mine the cause of the failure.
2. System board.
1. Check cable to op-panel
2. Replace op-panel
3. I/O board (See notes on 3-1.)
Refer to "Step 1540-25" on page 2-61.
1. I
2
C bus error.
2. Call for support.
1. Remove cards.
2. Verify part numbers.
3. Install valid cards.
4. Call for support.
Chapter 3. Error Code to FRU Index
3-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs/6000 h seriesRs/6000 h50Rs/6000 h70

Table of Contents